Hello, welcome to visit Oufu Optoelectronics,We are a Chinese សៀវភៅ អូបែល manufacturer
Whatsapp:+86 13904053308
ផ្ទះ > ព័ត៌មាន > ព័ត៌មាន បណ្ដាញ > បន្ថែម

ទាក់ទង របស់ អ្នក

កម្រិត ព័ត៌មាន អុបទិក កណ្ដាល, Ltd

អាសយដ្ឋាន ៖ Shenyang, Liaoning, China.
ទំនាក់ទំនង ៖ កម្មវិធី គ្រប់គ្រង ZhangName
ទូរស័ព្ទ ៖ 400- 964-1314
ទូរស័ព្ទ ចល័ត ៖ 86 13904053308
រក្សា ទុក

ព័ត៌មាន បណ្ដាញ

ADSS Fiber Optic Cable Installation? 5 Fiber Cable Pro Tips

2025-06-11 34

Why Proper ADSS Installation Matters

ADSS សៀវភៅ អូបែល installation requires special care. Unlike traditional cables, these all-dielectric self-supporting cables need precise handling. In our 2025 airport project, improper tensioning caused 3 cable failures before we implemented these solutions.

Tip 1: Pre-Installation Planning (5 Critical Steps)

  1. Route Survey - Check for obstacles every 50ft

  2. Load Calculation - Max tension ≤ 20% RTS

    Www.adsscable.cn

  3. Hardware Selection - Use ADSS-specific dead-ends

  4. Weather Check - Avoid installation below -10°C

  5. Permit Verification - Especially near power lines

⚠️ Warning: Skipping load calculations causes 42% of failures (FOA 2024 report).

Tip 2: Tension & Sag Control

FactorIdeal RangeConsequences of DeviationTension15-20% RTS>25% risks fiber strainSag1-3% spanExcess sag causes wind damageSpacing3-5ftCloser spacing increases load

Fun fact: Proper sag reduces ice accumulation by 60% (IEEE 2025).

Tip 3: Hardware Installation Techniques

  • Use spiral vibration dampers every 100ftWww.adsscable.cn

  • Install armor rods at suspension points

  • Apply UV-resistant grease on fittings

Counterintuitively, overtightening hardware weakens the cable 30% faster.

Tip 4: Splicing Best Practices

During our Chicago project:

  • Maintained 0.3dB max splice loss

  • Used pressurized closure boxes

  • Documented every splice point

Tip 5: Post-Installation Testing

  • OTDR testing within 24 hours

  • Visual inspection checklistWww.adsscable.cn

  • Load retest after 30 days

ADSS Installation Checklist

  • [ ] Verify cable type matches design

  • [ ] Confirm proper tensioning equipment

  • [ ] Check all hardware compatibility

  • [ ] Test before final tensioning

  • [ ] Document complete as-built drawings

Remember: ADSS សៀវភៅ អូបែល installation succeeds when you respect its unique requirements.